CABLE > Coaxial Cables
> RG/U (75 Ø)
|
APPLICATION |
| |
| These cables
are used for MATV, RF TRANSMISSION, BROADCASTING,
LOCAL AREA NETWORK. |
|
|
CONSTRUCTIONS & TECHNICAL SPECIFICATIONS
|
| |
|
| |
| |
Type |
AWG (app.) |
Insulation & Nominal O.D. |
Nom.
Nominal O.D. mm |
Shield Mat. & Coverage |
Nom.
Imp.
Ø |
Nom. Vel. Prop. |
Nom. Cap. pF/m.
pF/m |
Nom. Att. |
| Mhz |
dB/100m |
 |
RG-59/U Belden 8241
|
22
(0,643mm)
Solid Copper Covered Steel
180,5 Ø/km |
3,70
mm
PE |
6,15
mm Black PVC |
85%
Bare Copper Braid |
75 |
66% |
67,3
|
50 |
7,9
|
| 100 |
11,2 |
| 200 |
16,1 |
| 400 |
31,8 |
| 700 |
31,8 |
| 900 |
36,4 |
 |
RG-59/U
Belden 9259 |
22
(7x0,254mm)
Bare Copper
49,2 Ø/km |
3,70
Foamed PE |
6,15
mm
Black PVC |
95%
Bare Copper Braid |
75 |
78% |
56,8 |
50 |
6,9 |
| 100 |
9,8 |
| 200 |
14,8 |
| 400 |
21,7 |
| 700 |
29,2 |
| 900 |
33,1 |
 |
RG-59
Belden 8279A |
23
(7x0,20mm)
Stranded Copper 62,6 Ø/km |
3,70
mm FR.SF PE |
5,60
mm
Black PVC |
85%
Tinned Copper Braid |
75 |
66% |
68,5 |
50 |
9,2 |
| 100 |
13,1 |
| 200 |
19,4 |
| 400 |
27,9 |
| 700 |
37,4 |
| 900 |
42,7 |
 |
RG-59B/U
Belden 8263 |
23(0,584mm)
Solid Copper Covered Steel
154,2 Ø/km |
3,70
mm PE |
6,15
mm NC-PVC Black |
95%
Bare Copper Braid |
75 |
66% |
67,2 |
50 |
7,9 |
| 100 |
11,0 |
| 200 |
16,1 |
| 400 |
23,0 |
| 700 |
31,8 |
| 900 |
36,4 |
 |
RG-6/U |
17
(1,00mm)
Solid Bare Copper
24,6 Ø/km |
4,57
mm Foamed PE |
6,90
mm Black PVC |
60%
AlPET Foil + Tinned Copper Braid |
75 |
78% |
56,7 |
50 |
4,9 |
| 100 |
6,9 |
| 200 |
10,2 |
| 400 |
14,4 |
| 700 |
19,7 |
| 900 |
22,6 |
 |
RG-11/U
Belden 8213 |
14
(1,63 mm)
Solid Bare Copper
8,5 Ø/km |
7,30
mm Foamed PE |
10,30
mm Black PVC |
97%
Bare Copper Braid |
75 |
78% |
56,7 |
50 |
3,3 |
| 100 |
4,9 |
| 200 |
7,2 |
| 400 |
10,5 |
| 700 |
15,1 |
| 900 |
17,1 |
 |
RG-11/U
Belden 8238 |
18
(7x0,404mm)
Tinned Copper
20,0 Ø/km |
7,30
mm PE |
10,30
mm Black PVC |
97%
Bare Copper Braid |
75 |
78% |
67,2 |
50 |
4,3 |
| 100 |
6,6 |
| 200 |
9,5 |
| 400 |
13,8 |
| 700 |
19,0 |
| 900 |
22,3
|
 |
RG-11/AU |
18
(7x0,404mm)
Tinned Copper
20,0 Ø/km |
7,30
mm PE |
10,30
mm NC-PVC Black |
97%
Bare Copper Braid |
75 |
78% |
67,3 |
50 |
4,3 |
| 100 |
6,6 |
| 200 |
9,5 |
| 400 |
13,8 |
| 700 |
19,0 |
| 900 |
22,3 |
 |
RG-216/U |
18
(7x0,404mm)
Tinned Copper
20,0 Ø/km |
7,30
mm PE |
10,30
mm NC-PVC Black |
97%
2 Kat Bare Copper Braid |
75 |
66% |
67,2 |
50 |
4,3 |
| 100 |
6,6 |
| 200 |
9,5 |
| 400 |
13,8 |
| 700 |
19,0 |
| 900 |
22,3
|
|
| |
|
|